$ 3700.00
5000S Multi-Parameter Laboratory Water Quality Analyzer
  • Detail
  • Parameters
  • Review

Main features

  Up to nine parameters can be measured simultaneously. Conductivity, TDS, Resistivity, Temperature, pH, ORP, Dissolved Oxygen, Dissolved Oxygen Saturation, Residual Chlorine are measured simultaneously. The channels are independent of each other and do not interfere with each other. Industrial control watchdog: ensure the meter will not crash.


Technical indicators

  I. Display: Chinese liquid crystal display, Chinese menu operation.


  Second, conductivity:


  (1) Measuring range: electrode constant × (1 ~ 3000) μS/cm, 0 ~ 99.9 ℃; 0.01 ~ 30 μS/cm; (0.01 electrode); 0.1 ~ 300 μS/cm; (0.1 electrode); 1.0 ~ 3000 μS/cm; ( 1.0 electrode); 10 ~ 30000 μS/cm; (10.0 electrode).


  2) Accuracy: ±0.5%FS, ±0.3℃.


  III. pH:


  1) Measuring range: (0.00 ~ 14.00) pH;


  (2) Basic error of electronic unit: ±0.02pH;


  (3) Basic error of the instrument: ±0.05pH.


  IV. Temperature:


  (1) Measuring range: (0.0~100.0)°C;


  (2) Basic error of electronic unit: ±0.3℃;


  (3) Instrument basic error: ± 0.5 ℃ (0.0 ℃ ≤ T ≤ 60.0 ℃);


  4) Other range: ±1.0℃.


  V. ORP:


  (1) Measuring range: (-1999 ~ 1999) mV;


  (2) Basic error of electronic unit: ±1mV;


  (3) Basic error of the instrument: ±5mV.


  Sixth, dissolved oxygen:


  (1) Measuring range: 0~100.0 ug/L, 0.00~20.00mg/L, 0.0~200.0%;


  (2) Basic error of the whole machine: ug/L: ±1.0%FS; mg/L: ±0.5%FS, temperature: ±0.5℃.


  VII. TDS:


  (1) Measuring range: 0.000~999.9 mg/L, 1.000 g/L~19.99 g/L;


  (2) Basic error of electronic unit: ±1.0% (FS);


  (3) Basic error of the instrument: ±2.0% (FS).


  Eight, power supply: AC220V ± 22V, 50Hz ± 1Hz, optional DC24V ± 2.4V.


  Nine, resistivity:


  (1) Measuring range: 0 ~ 20.00 MΩ - cm;


  (2) Electronic unit basic error: ± 1.0% (FS);


  (3) Instrument basic error: ± 2.0% (FS).


  4)The channels are independent of each other, and the data of each channel are measured simultaneously.


  (5) Conductivity, temperature, pH, ORP, dissolved oxygen, residual chlorine is displayed on the same screen, and the others can be switched to display.


  Communication interface: isolated RS232.


  XI, power supply: AC220V ± 22V, 50Hz ± 1Hz.


  XII. Protection level: IP65.


  XIII, working conditions: ambient temperature 0 ~ 60 ℃, relative humidity ≤ 90 ℅.


  XIV, size, weight: 202x202x68mm, 1.0Kg.


Standard configuration

  5000S secondary meter, electrodes according to customer requirements.


Ordering Guide

  Please inform the number of parameters measured, to facilitate the configuration of electrodes, do not specify all the parameters of the electrode are equipped.


Price
$3700.00
Inventory
100000
Home
Customer service
shopping cart
ADD TO CART
BUY NOW